Contact Number
+86 400-887-6000
X Series
X Series
Process Calibrator
SUPCON X329 Process Calibrator is a handheld and battery-operated instrument. It could measures and sources a variety of electrical parameters which be widely applied in industrial fields and laboratories. And it has passed CE certification.
Features overview
A Split-screen Display
A Split-screen Display
A Split-screen Display
The upper display allows you to measure volts, current and thermocouples. The lower display allows you to measure and source volts, resistance temperature detectors (RTD), thermocouples (TC), resistance and frequency.
Measuring Temperature with Thermocouples or RTDs
Measuring Temperature with Thermocouples or RTDs
Measuring Temperature with Thermocouples or RTDs
The calibrator supports eight standard thermocouples, including types J, K, T, E, R, S, B or N. The calibrator supports six standard RTDs which are Cu50, Pt100, Pt100-3916, Pt200, Pt500 or Pt1000. The calibrator accepts RTD measurement input in two-, three-, or four-wire connections, with the three- wire connection the most common.
Zero Clearing
Zero Clearing
Zero Clearing
For sourcing or measuring DC voltage, resistance, RTDS and TC, offset errors caused by internal elements or external factors can be cleared by the CLEAR keys.
Ramping and Stepping the Output
Ramping and Stepping the Output
Ramping and Stepping the Output
Two ways are available for adjusting the value of source function: manual stepping and ramping the output.
A Split-screen Display
A Split-screen Display
A Split-screen Display
The upper display allows you to measure volts, current and thermocouples. The lower display allows you to measure and source volts, resistance temperature detectors (RTD), thermocouples (TC), resistance and frequency.
Measuring Temperature with Thermocouples or RTDs
Measuring Temperature with Thermocouples or RTDs
Measuring Temperature with Thermocouples or RTDs
The calibrator supports eight standard thermocouples, including types J, K, T, E, R, S, B or N. The calibrator supports six standard RTDs which are Cu50, Pt100, Pt100-3916, Pt200, Pt500 or Pt1000. The calibrator accepts RTD measurement input in two-, three-, or four-wire connections, with the three- wire connection the most common.
Zero Clearing
Zero Clearing
Zero Clearing
For sourcing or measuring DC voltage, resistance, RTDS and TC, offset errors caused by internal elements or external factors can be cleared by the CLEAR keys.
Ramping and Stepping the Output
Ramping and Stepping the Output
Ramping and Stepping the Output
Two ways are available for adjusting the value of source function: manual stepping and ramping the output.
Check Out All Products Parameters
SUPCON X229 Handhold Process Calibrator
SUPCON X329 Process Calibrator
You may also be interested in...
More Info